Poratble Three Phase Working Standard Reference Energy Meter

    

 


 

Name: Portable Three Phase Working Standard Reference Energy Meter
Model No.:SY3640
Brand Name:Songyang
Country of Origin:China
Minimum Order:1 Set
     
 

Introduction

SY3640 three-phase working standard meter is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.05.

Features and Main Function

  • 7″ true color TFT light LCD with 800 X 480 resolution ratio is adopted.

  • Touch screen and buttons can be operated more conveniently and quickly.

  • V, A, W, Var, PF, and Hz can be measured at the same time and error calibrated.

  • 0-51st harmonic can be analyzed.

  • Actual loading calibration of watt-hour meters with Q90 and Q60.

  • Measure CT variable ratio, ratio error, angle error and polarity.

  • 5A, 10A, 100A, 200A, 500A, 1000A, 2000A clamp CT is optional.

  • Communication: RS232C, USB Communication port is available.

Technical Specification

  • Voltage input:   30V—560V (60V/120V/240V/480V automatic shift).

  • Current input:   Direct mode: 0.05A—12A (automatic shift).

    Clamp CT: 5A, 10A, 20A, 100A, 200A, 500A, 1000A and 2000A for selection.

  • Phase measurement range: 0.000°~360° (or 0.000°~±180°),

    Resolution ratio: 0.001°.     Accuracy: ±0.05° (current input>10%Ib)

  • Frequency measurement:    resolution ratio: 0.001Hz,     Accuracy: ±0.01Hz 

  • Input electric energy pulse: TTL level, max. frequency ≤2MHz 

  • Output electric energy pulse: rated range is f=60kHz as automatic constant. It can be set between 1~250000 as hand constant

  • Temperature coefficient: 5ppm

  • Low voltage input impedance: >750KΩ

  • Accuracy:  Class 0.05, Class 0.1

  • Current input impedance: <0.05Ω

  • Input frequency range: 45~65Hz

  • Accuracy for PT secondary voltage drop (90%~110%Un): angle error 0.2min, ratio error 0.02%

  • Accuracy for PT, CT secondary load measurement: Class 1.0 Measurement range: admittance: 1.0~99.99 (ms), impedance: 0.1~8 (Ω)

  • Accuracy for clock measurement: ±0.5ppm; 0.05s/day

  • Power supply: frequency 50Hz, range 45~450V

  • Power consumption: ≤13VA

  • Operating ambient temperature; -10°C~40°C humidity: 30~80%RH

  • Size: 370mm (L)*260mm (W)*135mm (H)

  • Weight: 4kg

     

Back>>